Mohamed Sharif, Noor Fadzilah and Mohamed Shafiee, Khairun Neesya and Tajudin, Nur Fatin Izzati and Moh Nazar, Nazatul Shiema and Ahmad Tarmizi, Siti Noraziati and Abdul Rahman, Abdul Rashid and Samaila, Buda (2024) A modelling of 500 Kv long transmission line and fault detection using inverse definite minimum time over current (IDMT O/C) relay. In: The 5th International Conference on Integrated Engineering and Technology (INTCET 2024), 4 September 2024, Palm Garden Hotel, PutraJaya. (Submitted)
AModellingOf500Kv.pdf - Full text
Restricted to Repository staff only until 31 January 2099.
Download (6MB)
Abstract
As electricity demand increases day by day due to economic growth the process of transmitting efficient electrical power is vital. Thus, a power simulation study is required to determine the mechanism of the transmission line, and possible faults that occurred in the transmission line system. On a daily basis, single line to groundfault (L-G), double line to ground fault (2L-G), and triple line to ground fault (3L-G) are the faults that normally occur in the long transmission line system. In this project, a model of a 300km/500 kV EHV transmission line consisting of a three-phase source, distribution line, and load is simulated using MATLAB software. When the L-G fault is applied, the voltage is diminished to zero and upon fault clearance. the R—G line produced overvoltage and overcurrent by 518.9 kV and 1889 A, which increased about 46.83% and 15.67% compared to normal lines of Y—G and B—G at 353. kV and 1633 A. Then, for the 2L-G fault again the voltage is reduced to zero and when fault clearance occurred, the R-G and Y-G lines experienced overvoltage and overcurrent at 570.4 kV and 708.5kV. which showed more than 60% transient compared to normal line B-G at 353.4 kV. In Contrast, the 3L—G fault causes all transmission lines to experience overvoltage and overcurrent at different times and can damage the whole transmission system. Thus, to reduce the severe impact of fault, the Inverse Definite Minimum Time Over Current (IDMT O/C) relay protection is installed in the line model.
| Item Type: | Conference or Workshop Item (Paper) |
|---|---|
| Uncontrolled Keywords: | Faults in transmission line, Extra High Voltage (EHV), Simulink/MTLAB, IDMT O/C |
| Subjects: | T Technology > T Technology (General) T Technology > TK Electrical engineering. Electronics Nuclear engineering |
| Divisions: | Faculty of Engineering |
| Depositing User: | Mr Shahrim Daud |
| Date Deposited: | 13 Jan 2026 08:54 |
| Last Modified: | 13 Jan 2026 08:54 |
| URI: | http://repo.upnm.edu.my/id/eprint/683 |